Worcester Boiler Fault Code Hub – Complete Troubleshooting Guide for Every Model

This Fault Code Hub is designed for homeowners, landlords and engineers seeking clear, model-specific explanations of Worcester boiler fault codes. It covers legacy, discontinued and current models, explaining what each code means, why it happens and what action to take next.

Safety note: Reset the boiler only once. Repeated lockouts require the services of a Gas Safe-registered engineer.

Worcester Greenstar i System / Combi Boiler Fault Codes

Popular models: Greenstar 25i & 30i
Status: Discontinued (replaced by Greenstar 4000)

FD – Power Interrupted

Description: The Boiler has lost electrical power
Cause: Power cut, blown fuse, loose spur connection
What to do:
• Check mains power and boiler fuse
• Restore power and reset once
• Call an engineer if it keeps recurring

C7 – Fan Not Running on Start-up

Description: Fan fails to start
Cause: Fan motor fault or wiring issue
What to do:
• Check for visible blockages
• Reset boiler
• Fan replacement required if fault returns

C6 – Fan Speed Too High or Too Low

Description: Fan running outside safe limits
Cause: Dirty fan, faulty sensor, PCB issue
What to do:
• Power off and reset
• Engineer to clean or replace the fan

C1 – Fan Stopping During Operation

Description: Fan cuts out mid-cycle
Cause: Loose wiring or failing fan
What to do:
• Reset boiler
• Electrical inspection required

C4 – Fan Has Failed to Stop

Description: The Fan continues running when it should stop
Cause: Control board or relay fault
What to do:
• Switch off the boiler
• PCB replacement is usually required

E2 – Flow Temperature Sensor Issue

Description: Incorrect flow temperature reading
Cause: Faulty NTC sensor or wiring
What to do:
• Check connections
• Sensor replacement if error persists

E9 – Flow Temperature Exceeded 95°C

Description: Boiler overheated
Cause: Pump failure, airlock, blocked system
What to do:
• Bleed radiators
• Check pressure
• System flush or pump repair

EA – No Ionisation Detected After Ignition

Description: Burner failed to light
Cause: Gas supply issue, ignition electrode fault
What to do:
• Check gas supply
• Reset once
• Engineer inspection required

FA – Flame Detected After Gas Valve Closed

Description: Unsafe flame signal
Cause: Gas valve or PCB fault
What to do:
• Do NOT repeatedly reset
• Gas valve replacement required

F7 – Ionisation Detected Before Burner Start

Description: Flame signal is present incorrectly
Cause: Electrode or gas valve issue
What to do:
• Reset boiler
• Professional repair required

9U / F0 / A8 / CC

Description: Control box or module error
Cause: Loose wiring, defective HCM or PCB
What to do:
• Power cycle once
• Module replacement is usually required

A1 – Pump Stuck or Running Dry

Description: Pump not circulating water
Cause: Low pressure, airlock, seized pump
What to do:
• Top up pressure
• Bleed system
• Replace pump if needed

D4 – Flow Temperature Rising Too Fast

Description: Poor circulation detected
Cause: Sludge, blocked heat exchanger, pump issue
What to do:
• System flush
• Check pump and valves

Worcester Greenstar Si Compact Fault Codes

T1–T6 – Test Mode Codes

Description: Internal diagnostic modes
Cause: Engineer testing or stuck sequence
What to do:
• Reset boiler
• No fault unless code remains

9A / 9U / B7

Description: Heat Control Module or PCB fault
Cause: Incorrect module or internal board failure
What to do:
• Correct module fitting
• PCB replacement if unresolved

C6 / C7 – Fan Fault

Description: Fan speed abnormal or not running
Cause: Fan obstruction or electrical fault
What to do:
• Clear blockage
• Fan replacement

D1 – Return Sensor Error

Description: Return temperature sensor issue
Cause: Wet, damaged or disconnected sensor
What to do:
• Dry or replace the sensor

EA / F7 / FA / FD

Description: Ignition or flame signal error
Cause: Electrode, ignition lead, gas valve
What to do:
• Reset once
• Engineer diagnosis required

Worcester CDi Classic Combi / Regular Boiler Fault Codes

A1 – Water Leak or Pump Dry

Description: Pump not circulating water
Cause: Leak, low pressure, air in system
What to do:
• Top up pressure
• Bleed system

A7 – DHW Sensor Fault

Description: Hot water temperature is incorrect
Cause: Faulty NTC sensor
What to do:
• Replace sensor

A8 – EMS Communication Error

Description: Loss of control signal
Cause: Cable or PCB issue
What to do:
• Check wiring
• Engineer repair

C6 – Fan Speed Too Low

Description: Insufficient airflow
Cause: Fan or flue issue
What to do:
• Fan replacement

EA / FA / F7 / FD

Description: Flame or ignition fault
Cause: Gas valve, electrode, PCB
What to do:
• Gas Safe engineer required

Worcester Greenstar 8000 Life / Style Fault Codes

224 V – Safety Temperature Tripped

Description: Boiler overheated
Cause: Low water pressure or circulation fault
What to do:
• Top up to 1.5 bar
• Press reset

227 V – No Flame Signal

Description: Ignition failed
Cause: Ignition electrode or gas supply issue
What to do:
• Reset once
• Engineer inspection

228 V – False Flame Signal

Description: Flame detected incorrectly
Cause: Ionisation fault
What to do:
• Electrode or valve replacement

360 V – Incorrect Code Plug

Description: Wrong module installed
Cause: Incorrect component
What to do:
• Fit the correct code plug

1010–1076 / 2920–2971

Description: Advanced sensor, pressure or gas faults
Cause: Multiple internal errors
What to do:
• Full diagnostic required

Worcester 4000 Boiler Fault Codes

1021 – Hot Water Sensor Fault

Description: DHW sensor not reading correctly
Cause: Sensor loose or failed
What to do:
• Refit or replace sensor

224 – Software Fault

Description: Internal software error
Cause: Firmware malfunction
What to do:
• Manufacturer engineer visit required

Worcester Greenstar Ri Boiler Light Codes

No Light

Description: The Boiler has no power
Cause: Fuse, spur or supply issue
What to do:
• Check power and fuse

Fast Flash

Description: Lockout condition
Cause: Fan, sensor or ignition fault
What to do:
• Reset once
• Engineer if repeated

Slow Flash

Description: Overheat or ignition lockout
Cause: Circulation or ignition problem
What to do:
• Bleed system
• Engineer inspection

Worcester GB162 Fault Codes

EA / 9A

Description: Ignition or gas valve error
Cause: Burner or valve malfunction
What to do:
• Gas Safe repair required

CE / D / E / F Codes

Description: Sensor or control unit faults
Cause: Wiring or board failure
What to do:
• Replace affected components

Frequently Asked Questions – Worcester Boiler Fault Codes

Why does my Worcester boiler keep showing a fault code?

Fault codes appear when sensors detect safety, ignition, circulation or electrical issues that require attention or professional diagnosis.

Is it safe to reset my Worcester boiler after a fault code?

You may reset once only; repeated resets can worsen faults and require a Gas Safe engineer inspection.

What is the most common Worcester boiler fault code?

EA is most common, indicating ignition failure caused by issues with the gas supply, electrodes or internal control faults.

What does the EA fault code mean on a Worcester boiler?

EA means no flame is detected after ignition, which is usually linked to problems with the gas supply, ignition electrode or PCB.

Can low water pressure cause Worcester boiler fault codes?

Yes, low pressure can trigger overheating, pump and sensor fault codes; topping up often resolves minor issues.

Which Worcester fault codes require an engineer's attention immediately?

Flame detection, gas valve issues, overheating and repeated lockout codes always require immediate attention from a Gas Safe engineer.

Do Worcester fault codes differ by boiler model?

Yes, fault codes vary between Greenstar, CDi, Si Compact, 8000 and Ri models due to different control systems.

Where can I find my Worcester boiler fault code?

Fault codes display on the boiler screen or via flashing indicator lights, depending on the model type.

When to Call an Engineer

  • Repeated lockouts
  • Flame detection errors (EA / FA / F7)
  • Overheating or gas-related faults
  • Any fault returning after reset